| Parameters | Units | XAS 300-100 | XAS 370-125 | XAS 400-100 |
|---|---|---|---|---|
| Actual free air delivery* | cfm | 300 | 370 | 410 |
| Normal effective working pressure | bar / psi | 7 / 102 | 8.6 / 125 | 7 / 102 |
| Air outlet valve | 1 X 1½” and 3 X ¾" | 1 X 1½” and *4 X ¾” | 1 X 1½” and *4 X ¾” | |
| Ashok Leyland | Model | W04D | W04CT | W04CT |
| Power | HP | 80 | 111 | 111 |
| Maximum effective receiver pressure (unloaded) | bar / psi | 8.5 / 123 | 10.1 / 146 | 8.5 / 123 |
| Full load RPM | rpm | 2300 | 2400 | 2400 |
| Unload RPM | rpm | 1400 | 1400 | 1400 |
| Capacity of compressor oil system | l | 19 | 22 | 22 |
| Capacity of standard fuel tanks | l | 100 | 100 | 100 |
| L X W X H (with undercarriage) | mm | 3375x1630x1990 | 3375x1630x1990 | 3375x1630x1990 |
| Dry weight (with undercarriage) | kg | 1360 | 1440 | 1440 |